Requirements
Electrical
|
Shock Hazard
|
(FOR EQUIPMENT WITH CE MARK ONLY!) To prevent electric shock hazard this appliance must be bonded to other appliances or touchable metal surfaces in close proximity to this appliance with an equipotential bonding conductor. This appliance is equipped with an equipotential lug for this purpose. The equipotential lug is marked with the following symbol. Equipotential Ground Symbol = |
Water Quality
To help ensure continued reliability of water components, adhere to the Henny Penny recommended water specification shown below:
Acceptable Element and Compound Levels
Element | Acceptable Compound Level |
---|---|
Fe (Iron) |
< .1mg/l |
Cl (Chlorine) |
< .1 mg/l |
Cl2 (Chlorides and Salts) |
< 150 mg/l |
General Water Properties
Water Property | Particle Level |
---|---|
PH | 7-8 |
Silica |
< 15 ppm |
Hardness |
< 3 grains |
Alkalinity |
< 20 ppm |
Dissolved Solids |
< 60 ppm |
Un-dissolved Solids |
< 5 microns |
Selecting a Location
Place the Humidified Holding Cabinet in an area that allows the doors to be opened without interference of loading and unloading product. Also, keep the unit level for proper operation.
NOTICE - |
No minimum clearances are required for the rear and sides of the cabinet. |