Operating the CountDown Timer Controls

Start-Up

  1. Turn the power switch to the ON position.

  2. The display shows the increase in temperature, indicating the unit is heating.
  3. When the preset temperature is reached, the HEAT ON LED turns off and the display stays at the preset temperature.

Temperature Regulation

  1. Press and hold the PROGRAM button.

  2. The control beeps and “Prog Enter Code” shows in display.

  3. Enter access code 1, 2, 3.

  4. Press the INCREASE or DECREASE buttons to change the flashing setpoint temperature.

  5. Press and hold the PROGRAM button to set the temperature and exit the programming mode.

Timer Operation

Each of the timers can be started, stopped, or canceled, and not affect the status of the other timers.

  1. Press the desired timer button.

  2. The time remaining shows in the display.

  3. At end of time cycle, an alarm sounds and “0:00” is displayed.

  4. Press the timer to stop alarm and “---” is displayed.

Press and hold an active timer to cancel.

Timer Regulation

All timers can be set to a different starting time.

Exit the program mode at any time by pressing and holding the PROGRAM button. Also, if no buttons are pressed for 2 minutes, programming is exited automatically.

  1. Press and hold the PROGRAM button.

  2. The control beeps and “Prog Enter Code” shows in display.

  3. Enter access code 1, 2, 3.

  4. Press the PROGRAM button, and “---” is displayed, along with all the timer settings.

  5. Press the desired timer and the starting time flashes.

  6. Press the INCREASE and DECREASE buttons to change the starting time.

  7. Press the timer button to set the new starting time, and now a different timer button can pressed, and it’s starting time can be changed.

  8. When finished setting timers, press and hold the PROGRAM button to exit programming.

If a power failure occurs while a timer is running, the timer resumes the countdown when power is restored.