Troubleshooting

To isolate a malfunction, proceed as follows:

  • Clearly define the problem (or symptom) and when it occurs.

  • Locate the problem in the Troubleshooting table.

  • Review all possible causes. Then, one-at-a-time, work through the list of corrections until the problem is solved.

Problem Cause Solution
Product not holding temperature

 

 

 

 

   
Thermostat set too low Increase thermostat setting by removing hole plug on control panel and turning the shaft clockwise with a screwdriver.
Bad air heater Check heaters and replace if bad
Blower not working Check blower and replace if bad

Doors/drawers left open

Keep doors/drawers closed except to load and serve product

Product held too long

Hold product only for recommended times

Control temperature set too low

Increase air temperature (CDT control only)

or

Increase thermostat setting by removing hole plug on control panel and turning the shaft clockwise with a screwdriver

Cabinet steaming product soggy

 

Too much humidity inside cabinet Remove one or more baffles from water pan
Unit not reaching set temperature

 

 

Doors left open

Keep doors closed except to load and serve product

Thermometer not indicating true temperature Check cabinet temperature with another thermometer; have thermometer replaced if necessary
Blower not working Check Blower and replace if bad

Unit not heating

 

 

 

 

Bad high limit

Check high limit; replace if bad

Bad air heater Check heaters and replace if bad

Faulty wiring

Check for loose connections or broken wires

Faulty thermostat Check thermostat

Water pan not filling

Water supply off or

disconnected

Check water supply line

Plugged water strainer Clean water strainer
Corroded water pan Clean water pan
Faulty or corroded water valve Clean water valve; replace if necessary
Faulty solid state timer Replace solid state timer
Water pan overflows

 

Water pan not installed or installed improperly Check water pan installation

Corroded water pan

Clean water pan

Faulty or corroded water valve Clean water valve; replace if bad
Faulty float switch Check float switch
Faulty solid state timer Replace solid state timer
With switch in ON position the cabinet is completely inoperative

 

Unit not connected to electrical supply Plug cord into electrical outlet
Open breaker or fuse Reset breaker or install new fuse in junction box

Faulty cord or plug

Check cord and plug

Faulty power switch Check power switch
Unit overheating

 

Faulty thermostat Check thermostat; replace thermostat

Faulty blower

Check blowers; replace blower

With power switch turned on, the blower and fan operate, but the power light is off and the unit won’t heat Open high limit

With unit cool, check high limit

If the high limit opened because of overheating, refer to Unit Overheats section of Troubleshooting Guide