Components
Item No. | Controls | Description |
---|---|---|
1 | Power Switch | A toggle switch that switches electrical current to the unit. |
2 | Power Indicator | Illuminates when the power switch is in the ON position and the components are energized. |
3 | Thermometer | Indicates the air temperature inside the cabinet. |
4 | Heat Indicator | Illuminates when the thermostat turns on the heaters. |
5 | Thermostat | An electromechanical device that controls the temperature inside the cabinet. |
6 | Blower Motor | Used to recirculate the hot humid air throughout the cabinet; there are two blower motor assemblies in the cabinets. |
7 | Heater | Two, open-resistance, wire type heaters that provide heat throughout the cabinet; a standard full sized 120 VAC unit will have 1000 watt heaters; a standard full sized 240 VAC unit will have 1500 watt heaters; a standard 120V, HHC-903 unit will have 750 watt heaters. |
8 | High Limit | A safety device mounted next to the heater which protects the unit from overheating. |
9 | Fuse | A protective device that breaks the circuit when current exceeds the rated value; the fuse provides an overload protection for the electrical components; to remove the fuse, twist and pull the cap; the fuse is used only on the 120V/2000 watt units. |
10 | Water pan | Holds the water for creating humidity in the cabinet. |
11 |
Venting System (Units with vent adjustment only) |
Controls the humidity levels in the cabinet. |