Problem | Cause | Correction |
---|---|---|
Power switch ON but fryer completely inoperative. | Open circuit | - Check circuit breaker - Check plug - Call for service |
Fryer and control are on but oil will not heat | - High limit trip - Drain valve open | - Reset high limit - Close drain valve |
Oil foams and / or boils over | - Water in oil - Wrong or bad oil - Improper filtering - Improper rinsing after cleaning | - Drain oil and clean - Use recommended oil - Perform daily filtration - Clean, rinse, thoroughly dry vat |
Oil will now drain from vat | Drain valve clogged with crumbs | Open valve and clear clog with drain brush |
Filter switch ON but motor does not run | Motor thermal protector tripped | Reset thermal switch |
Burn Risk To avoid burns, turn POWER switch to OFF before resetting pump motor. |
The filter pump motor is equipped with a manual reset button, located on the