C1000 Control

C1000 Control Decal

Item No.

Description

Function

1

Digital Display

Shows the oil temperature, the timer countdown in the Cook Cycle and the selections in the Program Mode.

- The temperature of the oil can be shown by pressing the program button once or twice to view set-point temperature.

- If oil temperature exceeds 425° F (218° C) the display reads “E-5, FRYER TOO HOT”.

2

Ready LED

This LED lights when the oil temperature is within 5 percent of the setpoint temperature, signaling the operator that the oil temperature is now at the proper temperature for dropping product into the vat.

3

Timer Button

The timer buttons are used to start and stop Cook Cycles.

4

Idle Button

The idle buttons are used to start an Idle Mode which reduces the temperature of the oil during non-use periods. Press and hold to exit the Idle Mode.

5

Program Button

The program button is used to access the Program Modes. Once in the Program Mode it is used to advance to the next parameter.

6, 7

Left Up-Down Arrow

Used to adjust the value of the currently displayed setting in the Program Mode and to change set-point temperature.

8, 9

Right Up-Down Arrow

Used to adjust the value of the currently displayed setting in the Program Mode and to change set-point temperature.