Checking the Temperature Probe Calibration
-
Heat peanut oil and stir completely until peanut oil temperature has stabilized and the Ready indicator is on.
-
Place and electronic thermometer about 3 inches below the peanut oil’s surface, in the center of the vat. Let the temperature stabilize and remember the reading.
-
Press the Info button to see the probe’s temperature reading.
If the displayed temperature is less than 5 degrees from the electronic thermometer’s temperature, see D 1, Color Adjustment in Diagnostic Mode Details Section. If temperature differs from 5 to 15 degrees, or still can’t get the correct color, have the probe calibrated. If temperature differs by more than 15 degrees, have probe replaced.