Proper Operation Checks
- 
                                                            
Ensure the indicator needle in the pressure gauge is reading in the Operating Zone. If pressure does not build, contact your local distributor.
 - 
                                                            
Check the drain valve and filter valve for leaks.
 - 
                                                            
At the end of the cook cycle check for the following:
- 
                                                                    
The timer sounds.
 - 
                                                                    
The fryer automatically depressurizes.
 
 - 
                                                                    
 
Checking the Filter Pump
Use the following testing procedure on new or old fryers.
- Ensure the fryer vat is empty of all oil and product.
 - 
                                                            
Open the front door of the fryer.
 - 
                                                            
Turn the main power switch to the pump position. Open the filter valve. You will hear the electric motor running.
                                                             - 
                                                            
Place your thumb over the open filter union flare. You should feel suction. If you do not, contact Henny Penny customer support or your local service technician.
 - 
                                                            
Close the filter valve. Turn off the pump.
 
| 
                                                                         NOTICE -  | 
                                                                    
                                                                         To avoid damage to the filter pump, only run the filter pump for a few seconds during testing.  | 
                                                                
NOTE: The electric motor bearings are permanently lubricated. Do not lubricate.
This completes the testing cycle. If any of the functions did not occur, recheck the installation. If a problem persists, refer to the other sections of this manual or call an authorized Henny Penny distributor.