Technical Data For CE/Australian/SANS Marked Products
Nominal Heat Input (Net): | |
Natural (I2ELL) = 19.8 KW (67,560 Btu/h) | |
Natural (I2H) = 21.1 KW (72,000 Btu/h) | |
Natural (I2E) = 21.1 KW (72,000 Btu/h) | |
Natural (I2E+) = 21.1 KW (72,000 Btu/h) | |
Natural (I2L) = 21.1 KW (72,000 Btu/h) | |
Natural (I2E (43.46 - 45.3 mj/m3 (0°c))) = 21.1 KW (72,000 Btu/h) | |
Liquid Propane (I3P) = 82.40 MJ/hr | |
Natural (12H) = 75.96 MJ/hr | |
Liquid Propane (I3P) = 21.1 KW (72,000 Btu/h) | |
Nominal Heat Input (Gross): | |
Natural (I2ELL) = 21.98 KW (75,000 Btu/h) | |
Natural (I2H) = 23.4 KW (80,000 BTU/hr) | |
Natural (I2E) = 23.4 KW (80,000 BTU/hr) | |
Natural (I2E+) = 23.4 KW (80,000 BTU/hr) | |
Natural (I2L) = 23.4 KW (80,000 BTU/hr) | |
Liquid Propane (I3P) = 22.9 KW (78,000 BTU/hr) | |
South Africa (NG) = 23.9 KW (81,550 BTU/hr) | |
South Africa (LPG) = 1.63 kg/hr | |
Supply Pressure: | |
Natural (I2ELL) = 20 mbar (2.0 kPa) | |
Natural (I2H) = 11 mbar (1.13 kPa) | |
Natural (I2E) = 11 mbar (1.13 kPa) | |
Natural (I2E+) = 11 mbar (1.13 kPa) | |
Natural (I2L) = 11 mbar (1.13 kPa) | |
Liquid Propane (I3P) =28 mbar (2.8 kPa) | |
South Africa (NG) = 11 mbar (1.13 kPa) | |
South Africa (LPG) = 28 mbar (2.8 kPa) | |
Australia (LPG) = 27.5 mbar (2.75 kpa) | |
Test Point Pressure: | |
Natural (I2ELL) = 9.7 mbar (0.87 kPa) | |
Natural (I2H) = 8.7 mbar (0.87 kPa) | |
Natural (I2E) = 8.7 mbar (0.87 kPa) | |
Natural (I2E+) = 8.7/10 mbar | |
Natural (I2L) = 10 mbar (1 kPa) | |
Liquid Propane (I3P) = 25 mbar (2.5 kPa) | |
South Africa (NG) = 8.7 mbar (0.87 kPa) | |
South Africa (LPG) = 25 mbar (2.5 kPa) | |
Injector Size: | |
Natural (I2ELL) = 2.08 mm | |
Natural (I2H) = 1.04 mm | |
Natural (I2E) = 1.04 mm | |
Natural (I2E+) = 1.04 mm | |
Natural (I2L) = 1.04 mm | |
Liquid Propane (I3P) = 0.66 mm (2.5 kPa) | |
South Africa (NG) = 1.04 mm | |
South Africa (LPG) = 0.51 mm | |
Restrictor Size: | Natural (I2E+) = 4.1 mm |
This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force and only used in suitably ventilated location. Read the instructions fully before installing or using the appliance.
Noise generated from this equipment is less than 70 dB(A).
For gas appliance installations in South Africa, the installation shall be carried out by a registered installer, and the installation shall comply with requirements of SANS 10087-1 or SANS827 as applicable.
Where this appliance is to be installed in Australia and/or New Zealand, the following information is applicable:
-
The appliance must be installed in accordance with the requirements of Installation Standard AS/NZS 5601, local authority, gas, electricity and other relevant statutory regulations.
-
The Installer must test the appliance for correct operation after installation before handover to the customer.
-
Warning statements:
-
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION
-
DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE
-
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE
-
DO NOT MODIFY THIS APPLIANCE
-
-
This appliance contains no user serviceable parts - servicing shall be carried out only by authorized personnel. For spare parts and service contact the manufacturer or authorized local agent for this product.