Controls and Indicators
Item No. |
Description |
Function |
---|---|---|
1 |
Heat On |
Lights when the control calls for heat; the elements come on and heats the oil |
2 |
Digital Display |
Shows all the functions of the Cook Cycle, Program Modes, Diagnostic Modes, and alarms |
3 |
Pressure On |
Only used on models that create pressure in the vat; this should not light |
4 |
WAIT |
Flashes when the oil temperature is not at the proper temperature for cooking product |
5 |
Ready |
Lights when the oil temperature is 5° F below to 15° F above the cooking temperature, signaling the operator that the oil temperature is at the proper temperature for cooking product |
6 |
Info button |
Press to display the following fryer information and status:
e. Oil Life Display (Only if “Change Oil” feature is enabled) f. Date and time If pressed in the Program Mode, shows previous settings. Pressing this along with accesses the Information Mode which has historic information on the operator and fryer’s performance
|
7 & 8 |
Up and Down arrow buttons |
Used to adjust the value of the currently displayed setting in the Program Modes |
9 |
Program button |
Press Info button left to access Program Modes; once in the Program Mode, it is used to advance to the next setting; if pressed along with it accesses the Information Mode which has historic information on the operator and fryer’s performance |
10 |
Timer button |
Used to start and stop Cook Cycles, and to stop the timer at the end of a Holding Cycle |
11 |
Menu card window |
The name of the food product associated with each product selection button; the menu card strip is located behind the decal |
12 |
Product Select buttons |
Are used to select the product for cooking; to use them to start Cook Cycles, see section 3, Special Program Mode item SP-10 |
13 |
Cook/Pump switch |
A 3-way switch with a center OFF position turn the switch to the COOK position to operate the fryer; turn the switch to the PUMP position to operate the filter pump; certain conditions must be met before operating the filter pump; these conditions are covered later in the Filtering Section of this manual |
14 |
Idle mode button |
Used to manually enter an Idle Mode, or Clean-Out Mode |