Information Mode

This mode gathers and stores historic information on the fryer and operator’s performance.

Press right Program button  and Info button at the same time and  “*INFO MODE*” shows on display.

Press right Program button or Info button to access the steps and press Down arrow button to view the statistics within each step. Information Mode is intended for technical use, but the operator can view the following information:

  1. E-LOG - last 10 errors and time they occurred

  2. LAST LOAD - information about the most recent Cook Cycle, or the cycle presently in progress

  3. DAILY STATS - information for the last 7 days.

  4. REVIEW USAGE- information accumulated since the last time this data was manually reset

  5. INPA VHDSF M - provides test of fryer inputs

  6. OUTP H*P- shows the state of heater and pressure

  7. OIL TMP - temperature of oil

  8. CPU TMP - temperature of PC board

  9. PRINT REPORT - 10,000 activity log events, a list of programmed settings, and a report of operating statistics

  10. ANALOG - status of controller’s a-to-d converter

Press and hold right Program button to exit Information Mode at any time, or after 2 minutes, controls automatically exit back to normal operation.