Troubleshooting
To avoid severe personal injury, do not operate unit if pressure gauge shows high pressure conditions. |
Immediately place the cook/pump switch in the off position, which releases the pressure by allowing the unit to cool. Do not resume use of unit until cause of high pressure has been found and corrected.
Problem |
Cause |
Correction |
---|---|---|
Power switch on but fryer completely inoperative |
Open circuit |
Fryer plugged in Check breaker or fuse at wall |
Pressure not exhausting at end of Cook Cycle | Solenoid or exhaust line clogged | Turn OFF and allow fryer to cool to release the pressure in vat; have all lines, solenoid, and exhaust tank cleaned |
Operating pressure too high | Deadweight clogged |
Turn OFF and allow fryer to cool to release the pressure in vat; clean deadweight; see Cleaning the Deadweight Assembly |
Pressure does not build |
Not enough product in vat Metal shipping spacer not removed from deadweight assembly. Pressure not programmed Lid gasket leaking |
Place full capacity product in vat when using fresh oil Remove shipping spacer; see Unpacking Check programming Reverse or replace lid gasket |
Oil not heating |
Gas valve knob turned to the OFF position Drain valve open High temperature limit tripped |
Make sure gas control valve knob is turned to the ON position Close drain valve Reset high temperature limit; see Operating Controls Section |
Foaming or boiling over |
See Boil-Over chart on fryer and beginning of Operation Section in this manual |
Follow boil-over procedures from chart |
Oil not draining |
Drain valve clogged |
Push cleaning rod through open drain valve. |
Filter motor won’t run |
Motor overheated |
Reset motor; see Filter Motor Protector Manual Reset Section |
Product Color Not Correct: A. Too Dark |
Temperature too high Breading too far in advance Overshooting the setpoint temperature |
Check temperature setting in the Program Mode Bread product closer to frying period Adjust PC Factor (may require a service call). |
B. Too Light |
Temperature too low Fryer incorrect preheat Wrong product button pressed |
Check temperature setting in the Program Mode Allow proper preheat time Be sure to press the correct product to be cooked |
C. Product Greasy |
Oil old Temperature too low Vat overloaded Product not removed from vat immediately after end of cycle |
Replace oil Check temperature setting in the Program Mode Reduce cooking load Remove product form vat promptly |
The filter pump motor is equipped with a manual reset button, located on the
Burn Risk To avoid burns, turn POWER switch to OFF before resetting pump motor. |