Error Codes
In the event of a system failure, an error code displays and a constant tone is heard. To silence the tone, press any button.
Code | Cause | Correction |
---|---|---|
E-1 | Low oil in vat | Check oil level in JIB (oil reservoir). |
E-4 CPU TOO HOT | Control board overheating | Turn switch to OFF position, then back to ON. If E-4 persists, the control board is getting too hot. Check the louvers on each side of the unit for obstructions. |
E-5 FRYER TOO HOT | Oil overheating | Turn switch to OFF position, then back to ON. If E-5 persists, the heating circuits and temperature probe should be checked. |
E-6a FRYER TEMP SENSOR | Temperature probe open | Turn switch to OFF position, then back to ON. If E-6a persists, the temperature probe should be checked. |
E-6b FRYER TEMP SENSOR | Temperature probe shorted | Turn switch to OFF position, then back to ON. If E-6b persists, the temperature probe should be checked. |
E-10 HIGH LIMIT TRIP | High limit | Reset the high limit by manually pushing up on the red reset button. If the high limit does not reset, the high limit must be replaced. |
E-15 DRAIN IS OPEN | Drain switch failure | Close the drain using the drain valve handle. If E-15 persists, check the drain microswitch. |
E-18 LEVEL SENSOR FAILED | Level sensor open | Turn switch to OFF position and then back to ON. If display still indicates a failed sensor, have the connections checked on the control board. Have the sensor checked and replaced if necessory. |
E-19 PROTECTION SENSOR FAILED | Frypot protection sensor open | Turn switch to OFF position and then back to ON. If display still indicates a failed sensor, have the connections checked on the control board. Have the sensor checked and replaced if necessory. |
E-25 | Wrong or faulty elements or wiring problem | Have electrical supply, wiring, and elements checked. NOTE: Because of the seriousness of this error code, turn the POWER switch off and back on to cancel. |
E-26 HEAT AMPS ARE LOCKED ON | Faulty contactors or PCB | Have the contactors and PC board checked. NOTE: This error code could be displayed even with the POWER switch turned off. Unplug fryer or shut-off the wall circuit breaker to disconnect electrical power to fryer. |
E-41 E-46 | Programming failure | Turn switch to OFF position, then back to ON. If error persists, try to reinitialize the control (refer to Special Program Mode). If error code persists, replace the control board. |
E-47 |
| Press the power button to vat off and back on again, if E-47 persists do the following:
|
E-48 | Input system error | Have PC board replaced. |
E-60 | AIF PC board not communicating with control PC board | Press power button to turn vat off, wait 15 seconds and turn back on again. If E-60 persists, have connector between the PCB’s checked. Replace AIF PCB or control PCB board, if necessary. |
E-70 PWR SW OR WIRES FAILED |
| Have POWER switch checked, along with its wiring. Have I/O board checked. |
E-92 24 VOLT FUSE | 24-VAC fuse on I/O open or 14-pin cable connection issue |
|