INFO Button Stats
NOTE: If no buttons are pressed within 5 seconds in any of ststs mode, the controls revert back to normal operation.
Actual Oil Temperature
Press the INFO button and the actual oil temperature displays, for each vat.
Set-point Temperature
Press the INFO button twice and SP displays, along with the set-point (preset) temperature of each vat.
Recovery Information for each Vat
Press the INFO button 3 times and the following displays:
- No. of remaining cook cycles before Filter Lockout
- Average cook temperature
- Current temp. probe reading and rate of temp. rise
- Today’s date
- P=Protection Probe temperature
- L=Level Probe temperature Main Probe temperature