Error Codes
Display | Cause | Solution |
---|---|---|
"E-6B AIR TEMP SENSOR FAILED SHORTED" | Faulty air temperature probe | Turn switch to OFF position, then back to ON; if the display shows “E-6”, the temperature probe should be checked; once the temperature probe is repaired, or replaced, the controls should return to normal; if “E-6”persists, have PC board replaced |
"E-12A WATER HEATER SENSOR FAILED OPEN" | Faulty water heater probe | Turn switch to OFF position, then back to ON; if the display shows “E-12A”, the water heater should be checked and repaired or replaced (the water heater probe is built into the water heater); the controls should return to normal; if “E-12A” persists, have PC board replaced |
"E-12B WATER HEATER SENSOR FAILED CLOSED" | Faulty water heater probe | Turn switch to OFF position, then back to ON; if the display shows “E-12B”, the water heater should be checked and repaired or replaced (the water heater probe is built into the water heater); the controls should return to normal; if “E-12B” persists, have PC board replaced |
"E-17 HUMIDITY SENSOR FAILED" | Faulty humidity sensor | Turn switch to OFF position, then back to ON; if the display shows “E-17”, the humidity sensor should be checked; once the humidity sensor is repaired, or replaced, the controls should return to normal; if “E- 17” persists, have PC board replaced. See SP-4 to turn humidity OFF until service is provided |
"E-41 SYSTEM DATA LOST" | Memory scrambled | Turn switch to OFF position, then back to ON; if the display shows “E-41”, the control should be re-initialized (see Programming Section); if “E-41” persists, have PC board replaced |
"E-46 DATA SAVE FAILED" | Memory scrambled | Turn switch to OFF position, then back to ON; if the display shows “E-46”, the control should be re-initialized (see Programming Section); if “E-46” persists, have PC board replaced |
"E-80 VENT STUCK OR BAD SWITCH" | Vent on rear of module stuck or faulty vent activation switch | Check vent on rear of module for obstructions, or have vent activation switch replaced |
"WATER LEVEL LOW, PLEASE ADD WATER" (Manual fill) | Water pan low on water or empty | Fill water pan, in bottom of unit, to the maximum water fill mark; this warning won’t shut down the heat or humidity |
"WATER PAN NOT FILLING CHECK WATER SUPPLY" (Auto Fill) |
Water supply turned off |
Turn the water supply valve on |
Water flow reduced |
Adjust flow control valve | |
Fill solenoid relay bad |
Check solenoid relay |
|
Fill solenoid valve bad |
Check solenoid valve | |
"CALL SERVICE, WATER HEATER FAILURE" |
Water heater bad |
Check water heater |
Water heater relay bad |
Check water heater relay | |
"PURGE" |
Unit is purging humidity |
No corrective action is necessary. If message continues, contact Technical Support |
NOTICE - |
A humidity error only shuts down the humidity system. If a humidity error occurs, and you want to use the cabinet without humidity, turn the humidity off by following the directions for SP-4, Humidity Setpoint, in Special Programming Section of this manual. Once the setpoint is off, the alarm stops, but the error code shows in display. (Includes “E-12A”, “E-12B”, “E-17”) |