Troubleshooting
| Problem | Cause | Solution |
|---|---|---|
| Product not holding temperature
|
||
|
Control temperature set too low |
Increase air temperature |
|
|
Door gasket damaged or worn |
Replace bad door gaskets |
|
|
Bad air heater |
Check heaters and replace if bad See Tech Mode items 10 and 16 |
|
| Blower not working | Check blower and replace if bad See Tech Mode item 18 | |
|
Bad air heater, or blower relays |
Replace relay See Tech Mode items 10 and 16 |
|
| Bad high limit | Check high limit and replace if bad | |
|
Low or improper voltage |
Compare receptacle voltage to data plate voltage |
|
| Air probe faulty, open (“E-6A”), or shorted (“E-6B”) | Check probe resistance and replace, if necessary | |
| Cabinet steaming product soggy | Humidity setpoint too high | Decrease humidity setpoint |
| Water heater probe faulty, open (“E-12A”), or closed (“E-12B”) | Check probe resistance and replace, if necessary | |
|
Bad humidity sensor (“E-17”) |
Replace humidity sensor |
|
| Relay stuck closed | Replace relay | |
|
Vent stuck closed (“E-80”) |
|
|
| Product dry
|
Humidity set too low |
Increase humidity setpoint |
|
No water in pan |
Check water shut-off valve |
|
| Bad float switch | Replace float switch | |
|
Bad water heater high limit |
Replace high limit |
|
| Bad water heater | Check heater and replace if bad; see Tech Mode item 18 | |
|
Vent stuck open ("E-80") |
|
|
| Unit not reaching set temperature
|
Doors left open |
Keep doors closed except to load and serve product |
|
Door gasket damaged or worn |
Replace bad door gaskets |
|
| Thermometer not indicating true temperature | Check cabinet temperature with another thermometer; have thermometer replaced if necessary | |
| Blower not working | Check Blower and replace if bad | |
| Blower not working | Check Blower and replace if bad; see Tech Mode item 18 | |
|
Bad air heater |
Check heaters and replace if bad; see Tech Mode item 18 |
|
| Bad air heater, or blower relays | Replace relay | |
|
Unit not heating
|
Bad high limit |
Check high limit; replace if bad |
|
Bad control board |
Replace control board |
|
|
Bad air heater or blower relays |
Replace relay |
|
|
Bad air heater |
Check heaters and replace if bad; see Tech Mode item 18 |
|
|
Faulty wiring |
Check for loose connections or broken wires |
|
| Unit not heating |
Bad control board |
Check set point reading; if unit for heat below setpoint and not calling for heat, control board defective. Replace control board |
|
Blower not working |
Check blower and replace if bad; see Tech Mode item 18 |
|
| Relay stuck closed | Replace relay | |
|
Water does not drain |
Drain clogged |
Remove drain obstruction |
