Weekly Cleaning
Stand pipe could be hot! Allow to cool before removing or burns could result. |
To avoid burns, use PPE when removing concentration ring. |
NOTICE - |
To avoid damage to the unit, delime the unit weekly. |
- Turn off controls and water and remove pans and racks from cabinet.
-
Allow unit and water to cool, then pull stand pipe out of drain hole to empty water pan.
-
Remove concentration ring assembly from water pan.
-
Liberally spray the water pan with a concentrated deliming agent and let stand for 10 minutes.
-
Scrub the pan with a brush and flush with water.
-
Reinstall concentration ring assembly in the water pan.
NOTICE -
Ensure you install the racks correctly. Installing the lower racks in the upper rack location will lead to holding problems. The lower racks are shown below.
-
Reinstall the racks and fill the water pan with water to the maximum water fill line.
Unit is ready for use.