Performing the Initial Start-up

NOTICE -

Prior to use, thoroughly clean unit as described in Operator's Manual.

For Unit with CDT Controls

  1. To put the unit into operation, move the power switch to the ON position.

  2. Select either the A or B mode by depressing the UP button for A, or the DOWN button for B.

    The display shows an increasing temperature indicating the cabinet is heating. When the operating pre-set temperature is reached, the display reads 74ºC + 3ºC (165ºF + 5ºF) in the A mode, or 85ºC + 3ºC (185ºF + 5ºF) in the B mode.

  3. Place product inside the drawers, and press the appropriate timer button.

For Units with Electromechanical Controls

To put the unit into operation, move the power switch to the ON position.

The power indicator illuminates, indicating the unit is operating. The water light illuminates, indicating water is flowing into the water pan. When the pan is full, the light goes out and the water stops flowing.

A 10 second delay occurs before the float switch activates the water solenoid. This prevents overworking the components if the cabinet is bumped, or moved.

The heat light illuminates, indicating the unit is heating. Once operating temperature is reached, the light goes out. The operating temperature is factory preset and is reached within one hour.