Troubleshooting
To isolate a malfunction, proceed as follows:
-
Clearly define the problem (or symptom) and when it occurs.
-
Locate the problem in the Troubleshooting table.
-
Review all possible causes. Then, one-at-a-time, work through the list of corrections until the problem is solved.
Problem | Cause | Solution |
---|---|---|
Product not holding temperature
|
||
Bad air heater | Check heaters and replace if bad | |
Blower not working | Check blower and replace if bad | |
Doors/drawers left open |
Keep doors/drawers closed except to load and serve product |
|
Product held too long |
Hold product only for recommended times |
|
Control temperature set too low |
Increase air temperature (CDT control only) or Increase thermostat setting by removing hole plug on control panel and turning the shaft clockwise with a screwdriver |
|
Unit not reaching set temperature
|
Doors left open |
Keep doors closed except to load and serve product |
Faulty thermostat | Check thermostat and replace if needed | |
Blower not working | Check Blower and replace if bad | |
Unit not heating
|
Bad air heater | Check heaters and replace if bad |
Faulty wiring |
Check for loose connections or broken wires |
|
Faulty solid-state relay (CDT units only) | Replace solid-state relay | |
Faulty control board (CDT units only) | Replace control board | |
Faulty thermostat |
Check thermostat and replace if needed |
|
With switch in ON position the cabinet is
completely inoperative
|
Unit not connected to electrical supply | Plug cord into electrical outlet |
Open breaker or fuse | Reset breaker or install new fuse in junction box | |
Faulty cord or plug |
Check cord and plug |
|
Faulty power switch | Check power switch | |
Unit overheating
|
Faulty thermostat | Check thermostat; replace thermostat |
Faulty blower |
Check blowers; replace blower |
|
Faulty control board (CDT units only) | Replace control board. | |
With power switch turned on, the blower and fan operate, but the power light is off and the unit won’t heat | Open high limit |
With unit cool, check high limit If the high limit opened because of overheating, refer to Unit Overheats section of Troubleshooting Guide |