CountDown Timer Control Special Programming

Setup Mode

Setting the Temperature Units

  1. Press and hold the PROGRAM button for 4 seconds.

    “SetUP” and “Tech” are displayed.

  2. Press a timer button under the word “SetUP”. Ex: Setup 1 2 Press either 1 or 2.

  3. Enter access code 1, 2, 3.

    . “SetUP deg. F” is displayed.

  4. Press the INCREASE or DECREASE buttons to toggle from “F” (Fahrenheit) and “C” (Celsius).

  5. When correct setting displays, press the PROGRAM button to move to initialize system, or press and hold the PROGRAM button to exit programming.

CE and international units must have the temperature readings in Celsius. Follow above procedures and set to “C”.

Initializing the System

  1. Press and hold the PROGRAM button for 4 seconds.“SetUP” and “Tech” are displayed.

  2. Press a timer button under the word “SetUP”.

    Ex: “SetUP” Press either 1 or 2.

  3. Enter access code 1, 2, 3. 5. “SetUP deg. F” is displayed.

  4. Press PROGRAM button and “SetUP init sys” is displayed.

  5. Press and hold either the INCREASE or DECREASE button.

  6. The control beeps and the display counts down, 5, 4, 3, 2, 1, 0.

  7. When display reaches “0”, release the button and the initialization is complete. If the INCREASE or DECREASE button is released before “0” is displayed, the control will not initialize.

  8. Press the PROGRAM button to return to the Fahrenheit/Celsius mode, or press and hold the PROGRAM button to exit programming.

Tech Mode

The Tech Mode is mostly used at the factory level. The output tests and temperature probe calibration are given below. For further information, call the Technical Services Department at Henny Penny, +1-800-417-8405.

Output System

  1. Press and hold the PROGRAM button for 4 seconds.

    “SetUP” and “Tech” are displayed.

  2. Press a timer button under the word “Tech”.

    Ex: “Tech” Press either 4 or 5.

  3. Enter access code 1, 1, 2, 2, 1, 1, 2, 2.

    “outP test Htr” is displayed.

  4. Press the 5 timer button (under “Htr”) to turn heat and heat indicator on and off.

  5. Press the PROGRAM button to move to the next step, or press and hold the PROGRAM button to exit programming.

Temperature Calibration

  1. Press and hold the PROGRAM button for 4 seconds.“SetUP” and “Tech” are displayed.

  2. Press a timer button under the word “Tech”.

    Ex: “Tech” Press either 4 or 5.

  3. Enter access code 1, 1, 2, 2, 1, 1, 2, 2.

    “outP test Htr” is displayed.

  4. Press the PROGRAM button 3 times until “CAL OFS Hi Probe 185” is displayed.

  5. Press and hold number 1 timer (under “CAL”), while pressing the INCREASE and DECREASE buttons and set the display to match the actual cabinet temperature.

  6. Press the PROGRAM button to move to the next step, or press and hold the PROGRAM button to exit programming.