SimpleHold Control Special Programming

  1. With the Power Switch OFF, press and hold the SET button, and then turn the power switch on."F” or “C” displays.

  2. To toggle between Fahrenheit and Celsius, press the Up and Down arrows.

  3. After entering the Special Program Mode, press the SET button once and “int” displays.

  4. Press and hold the Up or Down arrow button and the display counts down “In3-In2-In1”. This reinitializes the controls and sets all controls to 0.

  5. After entering the Special Program Mode, press and release the SET button twice, and “Cal” shows in the display, followed by the current probe temperature. The probe can be calibrated + 10º F, and can be changed by using the Up and Down arrows.

  6. After entering the Special Program Mode, press and release the SET button three times, and “OP” displays. Use the Up and Down arrow buttons to toggle between “888” and a blank display. “888” turns all heat outputs on, and a blank display turns them off.

  7. After entering the Special Program Mode, press and release the SET button four times, and P=L, or P=U, displays.

  8. Use the Up and Down arrow buttons to toggle between L (lock), and U (unlock).