Performing the Initial Start-up

To avoid personal injury or property damage, before starting this procedure, move the main power switch to the off position. Disconnect the main circuit breakers at the circuit breaker box or unplug service cord from wall receptacle.

NOTICE -

Prior to use, thoroughly clean unit as described in Operator's Manual.

NOTICE -

Display may show "PURGING" when power is off.

This means humidity has reached 95% inside unit and the fan runs to help drop the humidity. Once the humidity reaches 92%, “POWER OFF” again shows in the display.

  1. Plug unit into electrical receptacle, or turn on wall circuit breaker. With the POWER switch turned to OFF the display shows “POWER OFF.”
  2. Turn the POWER switch to ON, and “PUSH TO PROOF” displays.

  3. Choose one of the following:

    • If the unit is to be used as a proofer,(80-140° F) (27-60° C), press the HUMIDITY button within 10 seconds, while “PUSH TO PROOF” still displays.

    • If not, allow unit to heat normally, (140-210° F) (60-99° C).

  4. Open door of unit and pour up to 3 gallons of water into bottom water pan, (minimum 1 gallon) up to the slot on the concentration ring.

  5. Press the temperature button to set the desired cabinet temperature. While the LED is flashing, press the up or down buttons until the desired temperature displays.

  6. Press the humidity button to set the desired cabinet humidity (OFF to 90%). While the LED is flashing, press the up or down button until the desired temperature displays.

  7. Allow the unit to preheat for about 1 hour prior to placing product in the cabinet. This allows the interior conditions to stabilize.