Display | Cause | Solution |
---|---|---|
“LO” | Food probe or actual temperature is below 50° F (10° C) in calibration mode only | Allow unit to heat up, or remove food from unit |
“HI” | Food probe temperature above 500° F (260° C) or lower temperature 275° F (135° C), or above | Turn unit off and call a certified service technician |
“E-4” | Control board temperature above 140° F (60° C) | Turn unit off and call a certified service technician |
“E-6” | Air probe error | Check probe connection at PC board, or call a certified service technician |
“E-41” | Scrambled PC board memory | Press UP button to clear “E-41;” if it reappears, call a certified service technician |
“E-56” |
Setpoint storage error |
Press UP button to clear “E-56,” then turn unit OFF and back ON; if “E-56” reap pears, call a certified service technician |