In the event of a control system failure, the digital an error message displays. The message codes are shown in the DISPLAY column below. A constant tone is heard when an error code displays, and to silence this tone, press any button.
| Display | Cause | Correction | 
|---|---|---|
| “E-4” | Control board overheating. | Turn switch to OFF position, then turn switch back to ON; if “E-4” displays, the control board is getting too hot; check the louvers on each side of the unit for obstruction. | 
| “E-5” | Oil overheating. | Turn switch to OFF position, then back to ON; if “E-5” displays, the heating circuits and temperature probe should be checked. | 
| “E-6A” | Temperature probe open. | Turn switch to OFF position, then back to ON; if “E-6” displays, the temperature probe should be checked. 
 | 
| “E-6B” | Temperature probe shorted. | |
| “E-10” "E-10 A" "E-10 B" "E-10 C" "E-10 D" "E-10 F" "E-10 M" "E-10 Y" | High limit High limit tripped above 300° F High limit tripped below 300° F High limit tripped while cooking High limit tripped less than 5 minutes of Auto Filter High limit tripped during filter cycle High limit tripped during melt mode High limit tripped less than 5 minutes of "YES" | Let the unit cool down (15-20 minutes), reset the high limit by pressing and holding the appropriate high limit reset switch for 5 seconds. If high limit does not reset, contact service provider. (Vat 1 refers to the far-left vat.) For single well units, open door and the reset switch is located up and underneath. 
                                                                         | 
| “E-15” | Drain switch. | Ensure drain knob is completely pushed-in; if E-15 per- sists, have drain switch checked. | 
| “E-18A” | Left level sensor open. | Turn switch to OFF position, then back to ON; if display still indicates a failed sensor, have the connections checked on the control board. Have sensor check and replaced if necessary. 
 
 | 
| “E-18B” | Right level sensor open. | |
| “E-18C” | Both level sensors open. | |
| “E-21” | Slow heat recovery. | Have a certified service technician check the fryer for cor- rect voltage to the unit; have heat circuit checked; have unit checked for loose or burnt wires. | 
| “E-22” ”NO HEAT” ”CHECK PWR CORD AND BREAKER” | Elements not heating. | Have power cord and heat circuit checked. | 
| “E-41” ”E-46” | Programming failure. | Turn power switch to OFF, then back to ON; if an error code displays, have the controls re-initialized; if error code persists, have the control board replaced. | 
| “E-47” | Analog converter chip or 12-volt supply failure. | Turn power switch OFF, then back to ON; if “E-47” per- sists, have the I/O board, or the PC board replaced; if speaker tones are quiet, probably I/O board failure; have the I/O board replaced. | 
| “E-48” | Input system error. | Have PC board replaced. | 
| “E-54C” | Temperature input error. | Turn power switch to OFF, then back to ON; have control PC board replaced if “E-54C” persists. | 
| “E-60” “FILTER IN USE” | AIF PC board not communicating with PC board. | Turn power switch to OFF, wait 15 seconds, then turn switch back to ON. If “E-60 persists, have connector be- tween the PC boards checked; replace AIF PC board or control PC board if necessary. | 
| “E-93” ”24 VDC SUPPLY TRIPPED” | Autolift motor malfunction or failure. | If AutoLift feature is not operating, have each of the Auto- lift motors checked. Check the 24V circuits. | 