Info Button and Filter Button Statistics
Info Button Stats
Menu Step |
Description |
---|---|
Actual Oil Temperature |
Press the info button 1 time and the actual oil temperature shows in the display for each vat. |
Set-Point Temperature |
Press the info button 2 times and “SP” shows in the display, along with the set-point (preset) temperature of each vat. |
Recovery Infor- mation For Each Vat |
Press the info button 3 times and REC shows in the left display and the recovery time that oil temperature went from 250°F (121°C) to 300°F (149°C) shows in the right display. For example, “REC 5:30” means it took 5 minutes and 30 seconds for the oil temperature to recover to 300° F (149°C) from 250°F (121°C). |
Filter Button Stats
Menu Step |
Description |
---|---|
Cook Cycles Re- maining Before Filtering |
Press either filter button 1 time. The left display shows “COOKS RE- MAINING” and the right display shows the number of cook cycles before the next auto filter. For example, “REMAINING” “3” “6”, means after 3 more cook cycles on the left vat, the controls asks the operator if they are ready to filter or not. But, 6 more cook cycles remain on the right vat. |
Time & Date |
Press either filter button 2 times, “FILTERED” shows in the displays, along with time-of-day and date of the last filter. |
Hours of Usage |
Press either filter button 3 times and “FLTR PAD” “XX HOURS” shows in displays to indicate the number of hours the existing filter has been used. |