YRI EEE 14X Specifications
Electrical Specifications
Models | Volts | Phase | Hertz | Amps | Kilowatts |
---|---|---|---|---|---|
14X |
208 | 3 | 60 | 39.4 | 14.0 kW |
14X | 240 | 3 | 60 | 34.2 | 14.0 kW |
14X | 220/380 | 3 | 50/60 | 24.3 | 14.0 kW |
14X | 230/400 | 3 | 50/60 | 24.3 | 14.0 kW |
14X | 240/415 | 3 | 50/60 | 24.3 | 14.0 kW |
Oil Capacity
30 lbs (13.6 kg) or 15 qts (14.2 liters) per full vat
30 lbs (13.6 kg) or 15 qts (14.2 liters) per full vat
15 lbs (6.8 kg) or 7.5 qts (7.1 liters) per split vat
15 lbs (6.8 kg) or 7.5 qts (7.1 liters) per split vat
15 lbs (6.8 kg) or 7.5 qts (7.1 liters) per split vat
Dimensions
Uncrated Dimensions
141 |
142 |
143 |
144 |
|
Width |
16.25 in (413 mm) | 31.25 in (794 mm) | 46.75 in (1187 mm) | 62.50 in (1588 mm) |
Depth |
32.25 in (819 mm) | 32.25 in (819 mm) | 32.25 in (819 mm) | 32.25 in (819 mm) |
Height |
45.75 in (1162 mm) | 45.75 in (1162 mm) | 45.75 in (1162 mm) | 45.75 in (1162 mm) |
Crated Dimensions
141 |
142 |
143 |
144 |
|
Length |
33.00 in (838 mm) | 38.00 in (965 mm) | 54.00 in (1372 mm) | 68.00 in (1727 mm) |
Depth |
21.00 in (533 mm) | 39.00 in (991 mm) | 39.00 in (991 mm) | 39.00 in (991 mm) |
Height |
52.00 in (1321 mm) | 55.00 in (1397 mm) | 55.00 in (1397 mm) | 55.00 in (1397 mm) |
Volume |
21 ft³ (0.59 m³) | 47 ft³ (1.4 m³) | 67 ft³ (1.9 m³) | 84 ft³ (2.4 m³) |
Shipping Weight
141 |
142 |
143 |
144 |
|
1 Full Vat |
302 lb (137 kg) | N/A | N/A | N/A |
1 Split Vat |
317 lb (144 kg) | N/A | N/A | N/A |
2 Full Vats |
N/A |
441 lb (200 kg) |
N/A | N/A |
2 Split Vats |
N/A | 472 lb (214 kg ) | N/A | N/A |
2 Full Vats/ 1 Split Vat |
N/A | N/A | 554 lb (252 kg) | N/A |
3 Full Vats |
N/A | N/A | 528 lb (240 kg) | N/A |
3 Split Vats |
N/A | N/A | 606 lb (275 kg) | N/A |
3 Full Vats/ 1 Split Vat |
N/A | N/A | N/A | 719 lb (326 kg) |
4 Full Vats |
N/A | N/A | N/A | 702 lb (319 kg) |
4 Split Vats |
N/A | N/A | N/A | 758 lb (344 kg) |
Front to rear dimension is 36- 7/8 “ (93.66 cm).
For doorways 36 in. (91.44 cm) or less, the protective bumper baron the rear of the fryer must be temporarily removed.