Troubleshooting

Problem

Cause

Correction

Power switch ON but fryer completely inoperative.

Open circuit.

Plug fryer in.

Check breaker or fuse at supply box.

Non-US/Some Int’l Locations Only Breakers in fryer tripped: open left door and reset breaker on fryer.

Oil heating too slow.

 

Low or improper voltage.Use a meter and check the receptacle against data plate.
Weak or burnt out element(s).Check heating element(s)
Point in contactor bad.Check contactor

Wire(s) loose.

Tighten.

Burnt or charred wire connection.Replace wire and clean connectors.

Control error code “E-10”.

Oil temperature too high.

Let unit cool down (15-20 minutes), push up on metal reset button under right side of the controls; if high limit does not reset, high limit must be replaced.

Vat is underfilled.

JIB is low or empty.

Fill the JIB.

JIB oil line is clogged or collapsed.

Check JIB line.

Filter pan needs

cleaned.

Clean filter pan and change paper or pad.

Oil foaming or boiling over top of vat.

Water in oil.

Drain and clean oil.

Improper or bad oil.

Use recommended oil.

Improper filtering.

Refer to filtering procedures.

Improper rinsing after cleaning the

vat.

Clean and rinse vat and then dry thoroughly.

Oil will not drain from vat.

Drain valve clogged with crumbs.

Open valve, force cleaning brush through drain. Remove the cleaning brush immediately so the drain valve does not close on the brush, which can damage the brush and drain valve. Skim vat more often to prevent clogs.

Drain trough clogged.

Remove right side panel and remove plug from end of trough, clean trough.

Filter motor runs but pumps oil slowly.

Filter line connections loose.

Tighten all filter line connections.

Filter paper or pad clogged.

Change filter paper or pad.

Filter not reassembled properly.

Refer to assembly instructions on inside door.

Bubbles in oil during entire filtering process.

Filter pan not completely engaged.

Ensure filter pan return line is pushed completely in- to the receiver on the fryer.

Filter pan clogged.

Clean pan and change paper or pad.

Damaged O-ring on filter line receiver on fryer.

Replace O-ring.

Control error code "E-31"Elements are up.Lower elements into vat.
Control error code "E-31"Elements are up.Lower elements into vat.

Filter motor will not run.

Thermal reset button on the rear of the pump motor is tripped.

Allow motor to cool, then, using a screwdriver, press hard against the button until it clicks.

Open circuit.Breakers in fryer tripped; open left door and reset breaker on fryer.
Power cord for vat # 1 is not plugged in.

Plug power cord into receptacle.

“IS POT FILLED” filter error prompt.All oil did not completely return after a filter cycle.Follow prompts. Is JIB full? If not, fill JIB.
“CHECK PAN” prompt.Filter pad clogged.Replace filter pad/clean pan.

“FILTER PAN MISSING” prompt.

Filter pan not completely engaged.

Adjust filter pan.

Filter pan missing.Find pan and replace.
Filter pan interlock not engaged.Adjust filter pan to engage interlock.
“CHANGE FILTER PAD” prompt appearsFilter pad has nto been changed within a 24 hr time period; Main power switch was turned off during filter pad changeReplace old filter pad with NEW filter pad while main power switch is in ON position. 24/7 stores should replace filter twice a day.
Drain pan microswitch stuckCheck microswitch.

Burn Risk

To avoid burns, turn POWER switch to OFF before resetting pump motor.