Technical Data For CE/AGA Marked Products

Nominal Heat Input (Net):  
Natural (I2ELL) = 19.8 KW (67,560 Btu/h)
Natural (I2H) = 19.8 KW (67,560 Btu/h)
Natural (I2E) = 19.8 KW (67,560 Btu/h)
Natural (I2E+) = 19.8 KW (67,560 Btu/h)
Natural (I2L) = 19.8 KW (67,560 Btu/h)
Natural (I2HS) = 19.8 KW (67,560 Btu/h)
Liquid Propane (I3P) = 19.8 KW (67,560 Btu/h)
Nominal Heat Input (Gross):  
Natural (I2ELL) = 21.98 KW (75,000 Btu/h)
Natural (I2H) = 21.98 KW (75,000 Btu/h) (79.13 MJ/h)
Natural (I2E) = 21.98 KW (75,000 Btu/h)
Natural (I2E+) = 21.98 KW (75,000 Btu/h)
Natural (I2L) = 21.98 KW (75,000 Btu/h)
Natural (I2HS) = 21.98 KW (75,000 Btu/h)
Liquid Propane (I3P) = 21.98 KW (75,000 Btu/h) (79.13 MJ/h)
Supply Pressure:  
Natural (I2ELL) = 20 mbar (2.0 kPa)
Natural (I2H) = 20 mbar (2.0 kPa)
Natural (I2E) = 20 mbar
Natural (I2E+) = 20/25 mbar
Natural (I2L) = 25 mbar
Natural (I2HS) = 25 mbar
Liquid Propane (I3P) = 30 mbar (3.0 kPa)
Liquid Propane (I3P) = 37 mbar (3.7 kPa)
Liquid Propane (I3P) = 50 mbar (5.0 kPa)
Test Point Pressure:  
Natural (I2ELL) = 9.7 mbar (0.87 kPa)
Natural (I2H) = 8.7 mbar (0.87 kPa)
Natural (I2E) = 8.7 mbar (0.87 kPa)
Natural (I2E+) = N/A
Natural (I2L) = 8.7 mbar
Natural (I2HS) = 8.7 mbar
Liquid Propane (I3P) = 25 mbar (2.5 kPa)
Injector Size:  
Natural (I2ELL) = 2.08 mm
Natural (I2H) = 2.08 mm
Natural (I2E) = 2.08 mm
Natural (I2E+) = 1.70 mm
Natural (I2L) = 2.30 mm
Natural (I2HS) = 2.30 mm
Liquid Propane (I3P) = 1.30 mm

This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force and only used in suitably ventilated location. Read the instructions fully before installing or using the appliance.

Noise generated from this equipment is less than 70 dB(A).