JIB Maintenance
Replacing The JIB
Control displays “JIB IS LOW” and an alarm sounds.
-
Open right door, pull JIB from unit, and pull cap from JIB top.
-
Discard empty JIB, and replace with full one.
Model EEG 241 Oil Reservoir
Filling Oil Reservoir
Control displays “JIB IS LOW” and an alarm sounds.
-
Open door and pull reservoir forward and remove reservoir cover.
-
Place reservoir cover on bracket on door.
-
Pour oil into reservoir up to fill lines and then replace cover and push reservoir back into position.
Removing/Cleaning Reservoir
-
Open door and pull reservoir forward.
-
Slide reservoir to the left and lift from fryer.
-
Clean reservoir at a sink with soap and water.
NOTE: Before placing the reservoir back into position, lubricate the O-rings on the filter tube with cold oil. Check O-rings for tears or nicks and replace if necessary. To replace O-ring, use a small, flat-bladed screwdriver, pry upon the O-ring and pull off of end of tube.