Planned Maintenance Schedule
As in all food service equipment, the Henny Penny open fryer does require care and proper maintenance. The table below provides a summary of scheduled maintenance procedures to be performed by the operator.
Procedure |
Frequency |
---|---|
Clean exterior of fryer. |
Daily |
Perform daily filter of oil on each vat. |
Daily |
Clean filter pan, install a new filter pad, lubricate the O-rings. NOTE: Replace O-rings if needed. |
Daily |
Clean and dry night covers, and then place over vats to protect oil from contamination. | Daily |
Lubricate filter pan O-rings. |
Every filter pad change. |
Change the oil. |
When oil smokes, foams up violently, or tastes bad. |
Dispose of stale oil and replace with fresh oil. |
As Required |
Deep clean the vat. |
Every change of oil or quarterly. |
Clean behind the fryer. CAUTION!:Disconnect power by unplugging power cord, to prevent personal injury. | Weekly |
Replace filter pan O-rings. |
Quarterly |
Perform the deep clean procedure. |
Quarterly |
Clean blower and vents. | Semi-annually |
Schedule service to perform planned maintenance per checklist. Contact distributor. | Annually |