Error Codes

In the event of a control system failure, the digital display shows an error message. The message codes are shown in the DISPLAY column below. A constant tone is heard when an error code is displayed, and to silence this tone, press any button.

Display Cause Solution

“E-4”

Control board overheating

Turn switch to OFF position, then turn switch back to ON; if display shows “E-4”, the control board is getting too hot; check the louvers on each side of the unit for obstructions

“E-5”

Oil Overheating

Turn switch to OFF position, then turn switch back to ON; if display shows “E-5”, the heating circuits and temperature probe should be checked

“E-6A”

Temperature probe open

Turn switch to OFF position, then turn switch back to ON; if display shows “E-6A”, the temperature probe should be checked

“E-6B”

Temperature probe shorted

Turn switch to OFF position, then turn switch back to ON; if display shows “E-6B”, the temperature probe should be checked

“E-10A”

“E-10B”

“E-10C”

“E-10D”

“E-10F”

“E-10M”

“E-10Y”

High limit tripped above 300° F

High limit tripped below 300° F

High limit tripped while cooking

High limit tripped within 5 minutes after self-detected that vat had refilled.

High limit tripped filtering or any use of filter menu option

High limit tripped during melt mode (exit melt at 180°F)

High limit tripped less than 5 minutes after user responded “YES” to an “Is Pot Filled?” question

Allow unit to cool (15-20 minutes) and reset high limit by pressing down and releasing raised side of the switch for the vat that is not operating; switches are located behind right door next to JIB.; if high limit does not reset, high limit must be replaced

"E-15"

Drain valve open

Clean and/or close fish vat drain valve; if clean and closed, have drain switch continuity checked

“E-18-A”

“E-18-B”

“E-18-C”

Left level sensor open

Right level sensor open

Both level sensors open

Turn switch to OFF position, then turn switch back to ON; if display still indicates a failed sensor, have the connectors checked at the control board; have sensor checked & replace if necessary

“E-20-A”

“FAN SENSOR STUCK CLOSED”

Pressure switch failure/ Wiring problem If fan is not running, have pressure switch checked; should be open circuit, if no air pressure If fan is running, wiring error

“E-20-B”

“NO DRAFT”

“CHECK FAN”

Pressure Switch failure/ hose loose

Draft Fan failure/ low voltage/ Flue or hood obstruction

Press power button to vat off and back on again, if E-20-B persists, have pressure switch checked; should be open circuit if no air pressure; make sure hose is connected to fan and pressure switch

Have draft fan checked; low voltage going to fan

Check the fryer flue and hood system for obstructions

“E-20-D”

“IGNITION”

“FAILURE”

Failure to ignite/ no flame sense Press power button to vat off and back on again, if E-20-D persists, check gas line connections; check gas shutoff valve; check ignition module; check gas valve; check flame sensor gap; check gas valve, and check ignition module wiring

“E-21”

Slow heat recovery

Have a certified service technician check the fryer for correct voltage to the unit; have the contactors and heating element checked; have unit checked for loose or burnt wires

“E-22”

“NO HEAT”

Burner not igniting Have gas valve and heat circuit checked

“E-41”,

“E-46”

Programming failure

Turn switch to OFF, then back to ON; if display shows any of these error codes, have the controls re-initialized; if error code persists, have the control board replaced

“E-47”

Analog converter chip or 12 volt supply failure

Turn switch to OFF, then back to ON; if “E-47” persists, have the I/O board, or the PC board replaced

“E-48”

Input system error

Turn switch to OFF, then back to ON; have control PC board replaced if “E-48” persists

“E-54C”

Temperature input error

Turn switch to OFF, then back to ON; have control PC board replaced if “E-54C” persists

“E-60”

AIF PC board not communicating with control PC board

Turn switch to OFF, then back to ON; if “E-60” persists, have the 1.5 amp fuse on the AIF PC board checked; have the connector between the PC boards checked; replace AIF PC board or control PC board if necessary

“E-62A”

Communication Error

  • Loose connection. Refer to Service Manual.

  • Replace control board.

  • Replace sensor

“E-70C”

Drain valve jumper wire missing or disconnected

Have the jumper wire checked on the PC board at drain switch interlock position

“E-82A”

Selector valve not detected

Have wiring checked between Selector Valve and AIF board

“E-82B”

Selector valve failed

Have the “Home” switch on Selector Valve checked

“E-82C” Selector valve failed Have wiring checked between the “Home” & “Position” switches and the Selector Valve; Have Selector Valve Motor checked; Have drive chain checked
“E-82D” Selector valve failed Have the “Home” switch and the “Position” switch on Selector Valve checked

“E-83”

“PRESSURE ”

“TOO HIGH”

Pressure transducer senses too high

pressure in AIF system

Check AIF system or the RTI quick disconnect; See details below;

“E-83A”

Pressure too high Vat #1 during filtering

Have AIF system in Vat #1 checked

“E-83B”,

Pressure too high Vat #2 during filtering

Have AIF system in Vat #2 checked

“E-83C”

Pressure too high Vat #3 during filtering

Have AIF system in Vat #3 checked

“E-83D”

Pressure too high Vat #4 during filtering

Have AIF system in Vat #4 checked

“E-83E”

Pressure too high Vat #5 during filtering

Have AIF system in Vat #5 checked

“E-83J”

RTI “JIB FILL” switch ON and pressure too high

Have JIB fill valves checked

“E-83R”

RTI “DISPOSE” switch ON and pressure too high

Check RTI quick-disconnect behind fryer; RTI phone no. if needed: 888-796-4997

“E-93A”

24VDC Tripped

Have motors for drain valves and selector valve checked