Accessing the Error Code Log (E-Log)
-
Press and hold the Temp and Info buttons until LEVEL - 2 displays, followed by ENTER CODE.
-
Using the first 4 product buttons, enter code 1, 2, 3, 4. “PROD” and “COMP” displays.
-
Press the Down arrow button and “E-LOG” displays.
-
Press the right Confirm button and “A” plus the present date & time flashes on the display, along with *NOW*”.
-
Press the Down arrow button and if an error was recorded, “B” and the date, time, and error code information displays. This is the latest error code that the controls recorded.
-
Press the Down arrow button and the next latest error code information can be seen. Up to 10 error codes (B to K) can be stored in the E-Log Section.
Press and hold the right Confirm button to view a brief description of the error.