Disposing of Oil into Disposal Container
|
To avoid personal injury:
|
The ODS holds approximately half the volume of oil contained in a Velocity vat. To prevent splashing and spillage, drain no more than half of the oil in to the ODS at one time.
|
Burn Risk To avoid burns, use PPE when connecting to or disconnecting from oil disposal unit. |
|
To avoid personal injury, ensure cover is in place before moving shuttle. |
-
Remove the oil disposal shuttle from under fryer and replace with the filter pan assembly.
-
Close and latch the cover and roll oil disposal shuttle to disposal container.
-
Press down on top of brake to secure unit in place.
-
Disconnect fitting from top of ODS and connect to disposal container.
-
Using the power cord on the back of the shuttle handle, plug it into the short cord from the junction box.
-
Turn power switch to the ON position.
-
Plug the shuttle electrical cord into the receptacle under the disposal container control, and then press & hold switch on container controls to pump oil from shuttle to the container.
-
Once shuttle is empty, release switch and unplug the electrical cord and wrap back onto the hook on the shuttle handle.
-
Using gloves or protective cloth, disconnect the fitting from the disposal container and connect it back onto the shuttle.