Assembling the ODS 460
|
Heavy Object Take care when moving the shuttle components to prevent personal injury. The shuttle weighs:
|
-
Open the shipping carton, and then remove the handle, hose, extension power cord, and hardware.
-
With help, remove the ODS unit from the shipping carton.
-
Using nuts and bolts provided, attach handle to handle bracket on top of oil tank, and then tighten to secure.
-
Using white pipe thread sealant, thread the threaded end of the hose into the top of the oil pump, and then tighten to seal.
-
Attach the quick disconnect end of the hose onto the oil tank's quick disconnect port.
-
Hang the extension power cord on the handle.
-
The shuttle works with multiple fryer models. Adjust the shuttle's sensor contactor accordingly, by removing the clevis pin, raising or lowering the sensor contactor, and then reinserting the clevis pin.
|
LVE1XX, LVG1XX, and PFE5XX, PFG6XX |
LVE2XX, LVG2XX, and F5 OFE5XX, OFG5XX and FFE5XX |
|
|