Error Codes
In the event of a system failure, an error code displays and a constant tone is heard. To silence the tone, press any button.
Display |
Cause |
Solution |
---|---|---|
E-4 | Control board overheating | Turn switch to OFF position, then back to ON. If E-4 persists, the control board is getting too hot. Check the louvers on each side of the unit for obstructions |
E-5 | Oil overheating | Turn switch to OFF position, then back to ON. If E-5 persists, the heating circuits and temperature probe should be checked. |
E-6a | Temperature probe open | Turn switch to OFF position, then back to ON. If E-6a persists, the temperature probe should be checked. |
E-6b | Temperature probe shorted | Turn switch to OFF position, then back to ON. If E-6b persists, the temperature probe should be checked. |
E-10 | High limit |
Allow oil to cool, and then reset the high limit by manually pushing and holding the reset (red rocker) switch for 5 seconds. If the high limit does not reset, please call technical support. |
E-15 | Drain switch failure | Close the drain using the drain valve handle. If E-15 persists, check the drain microswitch. |
E-31 | Fan jumper wire missing | Check for jumper wire on 12-pin connector and add if missing. |
E-41 E-46 |
Programming failure |
Turn switch to OFF position, then back to OON. If error persists, try to reinitialize the control (refer to Special Program Mode). If error code persists, replace the control board. |
E-54 |
PCB component failure |
Turn switch to OFF position, then back to ON. If E-54 persists, replace the PCB. |
E-70 | Faulty power switch, or switch wiring. Faulty I/O board | Have the power switch checked, along with its wiring. Have Input/Output board replaced if necessary. |