Error Codes

In the event of a system failure, an error code displays and a constant tone is heard. To silence the tone, press any button.

Display

Cause

Solution

E-4 Control board overheating Turn switch to OFF position, then back to ON. If E-4 persists, the control board is getting too hot. Check the louvers on each side of the unit for obstructions
E-5 Oil overheating Turn switch to OFF position, then back to ON. If E-5 persists, the heating circuits and temperature probe should be checked.
E-6a Temperature probe open Turn switch to OFF position, then back to ON. If E-6a persists, the temperature probe should be checked.
E-6b Temperature probe shorted Turn switch to OFF position, then back to ON. If E-6b persists, the temperature probe should be checked.
E-10 High limit

Allow oil to cool, and then reset the high limit by manually pushing and holding the reset (red rocker) switch for 5 seconds. If the high limit does not reset, please call technical support.

E-15 Drain switch failure Close the drain using the drain valve handle. If E-15 persists, check the drain microswitch.
E-31 Fan jumper wire missing Check for jumper wire on 12-pin connector and add if missing.

E-41

E-46

Programming failure

Turn switch to OFF position, then back to OON. If error persists, try to reinitialize the control (refer to Special Program Mode). If error code persists, replace the control board.

E-54

PCB component failure

Turn switch to OFF position, then back to ON. If E-54 persists, replace the PCB.

E-70 Faulty power switch, or switch wiring. Faulty I/O board Have the power switch checked, along with its wiring. Have Input/Output board replaced if necessary.