Special Programming Mode

The Special Program Mode is used to set more detailed parameters. The Special Program Mode is accessed by pressing and holding the PROGRAM SETTINGS (P) button for 8 seconds, or until the display shows “L-2”. “LEVEL 2” flashes in the top display, then “SP PRG” shows in the display. It then asks for a code which is 1, 2, 3.

To exit from the Special Program Mode, press and hold program P button for 2 seconds, or wait 2 minutes and control will automatically exit Special Program Mode.

Degrees Fahrenheit or Celsius (SP-1)

After entering the access code, the top display shows “SP-1” and “TEMP UNITS”. The middle display shows “°F” or “°C”. Pressing the UP or DOWN button will toggle the display from “°F” to “°C”, or vice versa.

Oven Type (SP-2)

After entering the access code (1,2,3), press and release the P button. “OVEN TYPE” shows in the top display and “Scr-6” or “Scr-8” shows in the middle display. This must match the type of unit before programming, or the unit may not perform properly. This will be preset from the factory. Pressing the UP and DOWN button will toggle the display from one unit to another.

Language (SP-3)

After entering the access code (1,2,3), press the P button twice and “LANGUAGE”, then “1=ENGL”, “2=FREN”, “3=GERM”, and “4=SPAN”. The middle display will show a digit, 1 thru 4. Pressing the UP and DOWN buttons under the digit will change the language that shows on the displays.

Audio Volume (SP-4)

The volume of the speaker can be adjusted. After entering the access code (1,2,3), press the P button three times. “AUDIO VOLUME” shows in the top display, and a digit 1 thru 10 shows in the middle display. 1 is the softest volume setting, 10 being the loudest. Use the UP and DOWN buttons under the digits to set the desired volume.

Audio Tone (SP-5)

The tone of the speaker can be adjusted. After entering the access code (1,2,3), press the P button four times. “AUDIO TONE” shows in the top display, and a number 50 thru 2000 shows in the middle display. 50 is the lowest tone setting, 2000 being the highest. Use the UP and DOWN buttons under the number to set the desired tone.

Alarm Auto Cancel (SP-6)

After entering the access code (1,2,3), press the P button five times. “ALARM AUTO CANCEL” shows in the top display, and “YES” or “NO” shows in the middle display. If this is set at YES, then when the programmed alarms go off the speaker will sound several beeps, then automatically stop. If it is set to NO, then someone has to press the alarm button before the speaker stops beeping. Use the UP and DOWN buttons under the middle display to toggle from YES to NO, or vice versa.

Cook-to-Hold-Auto (SP-7)

After entering the access code (1,2,3), press the P button six times. “COOK-TO-HOLD-AUTO” shows in the top display, and “YES” or “NO” shows in the middle display. If this is set to YES, then at the end of a Cook Cycle the speaker will beep several times and automatically goes into the Hold Mode. If it is set to NO, then someone has to press the STOP button before the speaker stops beeping and the Hold Cycle starts. Use the UP and DOWN buttons under the middle display to toggle from YES to NO, or vice versa.

Idle Mode Enabled (SP-8)

After entering the access code (1,2,3), press the P button seven times. “IDLE MODE ENABLED” shows in the top display, and “YES” or “NO” shows in the middle display. If this is set to YES, then “IDLE”... “SELECT PRODUCT”... “PUSH START TO PREHEAT” will scroll across the top display when the rotisserie is not in use. If it is set to NO, then at the end of a Cook Cycle the unit will start preheating again for the next Cook Cycle. Use the UP and DOWN buttons under the middle display to toggle from YES to NO, or vice versa.

Multiple Cook Steps (SP-9)

After entering the access code (1,2,3), press the P button eight times. “MULT COOK STEPS” shows in the top display, and “YES” or “NO” shows in the middle display. If this is set to YES, then more than one step can be programmed during a Cook Cycle. If it is set to NO, then only one time and temperature can be programmed per Cook Cycle. Use the UP and DOWN buttons under the middle display to toggle from YES to NO, or vice versa.

Programming Locked By Code (SP-10)

After entering the access code (1,2,3), press the P button nine times. PROG LOCKED BY CODE shows the top display, and YES or NO shows in the middle display. If this is set to YES, in the Program mode, 1-2-3 has to be entered before accessing the mode. If it is set to NO, then the Program Mode can be accessed without entering 1-2-3. Use the UP and DOWN buttons under the middle display to toggle from YES to NO, or vice versa. (The Special Program Mode always requires a code.)

Radiant Setpoint Offset (SP-11)

After entering the access code (1,2,3), press the P button ten times. “RADIANT SETPT OFFSET” shows in the top display, and “0°F” to “10°F” shows in the middle display. The radiant heaters can be set at a different shut-off temperature than the air heaters. Ex: If the display shows “10°F”, the radiant heat will not shut off until the air temperature reaches 10 degrees above the setpoint temperature. This feature can be used when cooking small loads which may need more consistent heat to get them done. Use the UP and DOWN buttons under the middle display to change the setting.

Initialize System (SP-12)

After entering the access code (1,2,3), press the P button eleven times. “DO SYSTEM INIT” shows in the top display, and “--- ” show in the middle display. This feature resets the controls to factory preset parameters, if the controls were preprogrammed, or will zero out the times and temperature. Press and hold either the UP or DOWN button in the middle display. The controls will beep, and the display will flash “in 3”, “in 2”, and “in 1”. Then the top display flashes “INIT” and “DONE”.

During the Special Program Mode, the different steps can be accessed using the PRODUCT SELECTION UP and DOWN buttons, or with the P button.