Manual Oil Disposal

To avoid severe burns and equipment damage:

  • Use PPE.

  • Allow the oil to cool to 100°F (38°C) before removing.

  • Only use a shuttle or approved container to transport oil.

  • Ensure the filter pan is empty prior to preforming these procedures.

  • Do not transport oil without cover in place.

  • Do not put water and/or cleaner in the shuttle; oil only.

  • Pumping hot oil through the unit damages the pump over time.

NOTICE -

To protect community sewer lines, oil must be trapped and disposed of through bulk removal. Hot oil can coagulate when cooled, which clogs pipes and sewer lines. Always dispose of oil in to an approved bulk oil disposal storage container or approved grease trap. Never pour oil down a public sanitation drain.

This section explains the manual process for draining and disposing of oil. Once the oil has degraded, the vat is drained completely and refilled with new oil. The degraded oil is manually transported to an oil storage container, using an Oil Disposal Shuttle (ODS).

Access the Dispose Menu

NOTE: An indicator light displays next to active options during procedure.

Use the following steps to access the disposal menu.

  1. Press and hold the Main menu button until *MAIN* displays. The Main menu displays.

  2. Press the 1. FILTER button. Additional menu items display.

  3. Ensure the filter pan is empty and then do the following:

    • If the filter pan is empty, press the Main menu button twice, and then continue at Drain the Oil.

    • If the filter pan contains oil:

      a). Press the Main menu button once, then press 5. FILL. b). Wait, oil pumps up to the vat.

      c). Press the Main menu button once, and then continue at Drain the Oil.

Drain the Oil

Using an Oil Disposal Shuttle (ODS) drain the oil from the vat by doing the following:

  1. Put on Personal Protective Equipment (PPE).

  2. Remove the filter pan and insert the ODS. Ensure the ODS's lid is open and the drain spigot aligns with the ODS opening.

  3. Press the 7. DISPOSE button. The message =DISPOSE= IS CART OR PAN IN PLACE? and YES NO displays.

  4. Press the YES button. DRAIN (hold) displays.

  5. Press and hold the DRAIN (hold) button until the ODS is half-full, then release.

  6. Remove the ODS carefully to prevent splashing and spillage, and then close and lock the lid.

  7. Transport the ODS to an approved oil storage container and empty.

  8. Repeat steps 5 through 7, making multiple trips until the vat is empty.

Purge the Fittings

Degraded oil remains inside the lines, valves and fittings. To completely purge the degraded oil, do the following:

  1. Press the next► button. The message =PURGE= Pump new oil push old oil from ports displays.

  2. Press the PUMP button. The pump runs for a few seconds, new oil pumps in to the vat, then the pump stops.

  3. If necessary, press the PUMP button again to ensure the lines, valves and fittings are purged.

  4. Press the next► button. The = WIPE = OPEN DRAIN option displays.

  5. Press the OPEN DRAIN button. OPENING... displays. Oil drains from the vat.

    =WIPE= Wipe pot with cloth or paper towel displays.

Wipe Out the VAT

To ensure degraded oil does not mix with new oil, do the following:

  1. Lift and secure the lid. Refer to Lifting and Securing the Lid for instructions.

  2. Use a cloth or paper towel to wipe the remaining oil down the vat drain and clean the vat surface.

  3. Remove the ODS carefully to prevent splashing and spillage, and then close and lock the ODS lid.

  4. Transport the ODS to an approved oil storage container and follow ODS procedures to empty the oil.

  5. When done, store the ODS in a safe location.

Fill the Vat with Oil

Fill the vat with new oil by doing the following:

  1. Press the next► button. EXIT DISPOSE? and YES NO displays.

  2. Press YES. - OFF - displays.

  3. Clean and dry the filter pan and install a new filter. Refer to Filter Pan Assembly for instructions.

  4. Insert the filter pan under the unit.

  5. Align and push the quick disconnect filter tube, on the filter pan, in to the filter tube receptacle on the bottom of the unit.

  6. Fill the vat to the lower limit line with fresh oil.

  7. Power on the fryer unit and return to normal operation.